Find great deals for Fluke A Digital Multimeter. Shop with confidence on eBay!. This unit is being sold “AS-IS”. Internal Battery Option. Unit works on battery or AC. Note battery probably will need charging. Did not test for battery life. This manual contains complete operating and maintenance instructions for the Fluke Models A and A Digital Multimeters. The information presented in.

Author: Tell Arasho
Country: Estonia
Language: English (Spanish)
Genre: Literature
Published (Last): 18 November 2004
Pages: 199
PDF File Size: 3.23 Mb
ePub File Size: 10.84 Mb
ISBN: 593-2-22879-876-1
Downloads: 99805
Price: Free* [*Free Regsitration Required]
Uploader: Arashira

The Performance Test is recommended as an acceptance test when the instrument is first received, and later as a preventive maintenance tool to verify proper instrument operation.

US-Instrument Services. Fluke A Digital MultiMeter

Also, the very high input impedance 75 MO minimizes circuit loading, thus contributing to measurement accuracy. There is one, user-replaceable fuse FI in your Multimeter. Figure describes how to 80112a your Multimeter for resistance measurements. True-rms is the effective value of any waveform and represents the energy level of the signal.

Set the instrument to the range and short the test leads.

Rent Fluke A DMM 3_-Digits, 10A, 2-Ohm | Transcat

8012aa Crest Factor Capability — 3 The error caused by exceeding the crest factor of 3. Please enter a valid ZIP Code. Remove the display assembly before washing the pcb and do not install it until the pcb has completely dried.

  BLESSED FREDERIC OZANAM PDF

Fuse F2 is rated for 3A at V. Warren, Michigan National Semiconductor Corp. Figure describes how to operate your Multimeter for conductance measurements.

The LCD may now be lifted free from the display mounting bracket. If your Multimeter has the – 01 Battery Option, refer to Section 6 for information on changing ac line voltages.

Figures and show the component locations for A and A Multimeters.

Install the clamp screw in the center mounting bracket using the nuts and washers provided. Current Shunt 80J The input divider attenuation provides additional protection on all other ranges. Rotate the display frame forward and down until the two hooks on the bottom of the display frame release the display mounting bracket. Set the DMM Calibrator for an output level of Meter Protection Circuits Remove the Multimeter from its container and place it in a convenient location.

On the UUT, select the 20V range. So, the positive half cycle of the 60 Hz noise cancels out the negative half cycle of the 60 Hz noise.

  CARL VINE FIVE BAGATELLES PDF

The conductance function of your Multimeter can be used to measure high resistive low leakage components diodes and capacitors while minimizing noise problems.

Reinstall the fuse and fuse holder. Figure describes how to operate the A for ac or dc current measurements up to lOA.

Fluke 8012A FOR RENT

If reshipment of the instrument is necessary, please use the original shipping container. The lOA function of the A has no fuse protection circuitry. All other components are external to U3.

Use the following procedure to verify the proper operation and accuracy of the DC Voltage function: The three resistance ranges with the diode symbol beside the range value provide a measurement voltage sufficient to cause a silicon junction to conduct.

The two devices are the Test Set and the 1.

Selecting either the resistance or conductance measurement function places Ql, Q2, and RT 1 in parallel with the meter across the resistance input and common lines. Report item – opens in a new window or tab.